3 changed files with 12 additions and 872 deletions
-
16src/db/db_service.cpp
-
13src/service/disfection_ctl/disinfection_service.cpp
-
855src/service/disfection_ctl/disinfection_service.cpp.bak
@ -1,855 +0,0 @@ |
|||
#include "disinfection_service.hpp" |
|||
|
|||
#include <cstring> |
|||
#include <iostream> |
|||
|
|||
#include "configs/gconfig.hpp" |
|||
#include "configs/project_setting.hpp" |
|||
#include "iflytop/components/uart_printer/uart_printer.hpp" |
|||
#include "iflytoplinuxsdk/src/iflytop/components/ziconv.hpp" |
|||
#include "service/device_state_service.hpp" |
|||
|
|||
// #define PROJECT_TYPE_LARGE_SPACE_DISINFECTION 1 // 大空间 |
|||
// #define PROJECT_TYPE_SMALL_SPACE_DISINFECTION 1 // 小空间 |
|||
|
|||
using namespace iflytop; |
|||
using namespace std; |
|||
#define DVALUE_COMPUTEPERIOD_TIME_S (10.0) |
|||
#define DUMP_LOG_PERIOD (5 * 60.0) |
|||
#define MAX_VOLUME (5000) |
|||
|
|||
namespace iflytop { |
|||
extern bool g_in_test; |
|||
|
|||
} |
|||
|
|||
static string formattimeS(int sec) { |
|||
if (sec >= 0) { |
|||
return fmt::format("{:0>2}:{:0>2}:{:0>2}", sec / 3600, sec % 3600 / 60, sec % 60); |
|||
} else { |
|||
return fmt::format("--:--:--"); |
|||
} |
|||
} |
|||
|
|||
static string getTime() { |
|||
struct tm tm = {0}; |
|||
|
|||
time_t t = time(nullptr); |
|||
localtime_r(&t, &tm); |
|||
return fmt::format("{:0>4}-{:0>2}-{:0>2} {:0>2}:{:0>2}:{:0>2}", tm.tm_year + 1900, // |
|||
tm.tm_mon + 1, // |
|||
tm.tm_mday, // |
|||
tm.tm_hour, // |
|||
tm.tm_min, tm.tm_sec); |
|||
} |
|||
|
|||
static bool zfeq(float a, float b, float eps = 0.01) { |
|||
if (fabs(a - b) < eps) { |
|||
return true; |
|||
} |
|||
return false; |
|||
} |
|||
|
|||
DisinfectionService::DisinfectionService() {} |
|||
void DisinfectionService::initialize() { |
|||
GET_TO_SERVICE(m_deviceIoControlService); |
|||
GET_TO_SERVICE(m_dbService); |
|||
GET_TO_SERVICE(m_disinfectionLogsManager); |
|||
GET_TO_SERVICE(m_disinfectionPrinterService); |
|||
|
|||
#if (defined PROJECT_TYPE_LARGE_SPACE_DISINFECTION) || (defined PROJECT_TYPE_SMALL_SPACE_DISINFECTION) || (defined PROJECT_TYPE_PIPE_DISINFECTION) |
|||
m_deviceIoControlService->replenishingFluidsPump_close(); |
|||
m_deviceIoControlService->sprayLiquidPump_close(); |
|||
|
|||
m_deviceIoControlService->heartingPlate_setPower(false); |
|||
m_deviceIoControlService->airBlower_setState(false); |
|||
m_deviceIoControlService->airCompressor_setState(false); |
|||
#elif (defined PROJECT_TYPE_DRAW_BAR_BOX) |
|||
m_context.beforeDisinfectantVolume_g = 0; |
|||
#else |
|||
#endif |
|||
|
|||
m_dvalueComputer.initialize(); |
|||
} |
|||
|
|||
string DisinfectionService::createDisinfectionID() { |
|||
struct tm tm = {0}; |
|||
|
|||
time_t t = time(nullptr); |
|||
if (t == -1) { |
|||
logger->error("time(nullptr) failed"); |
|||
exit(-1); |
|||
} |
|||
struct tm* tmp = localtime_r(&t, &tm); |
|||
if (!tmp) { |
|||
logger->error("localtime_r failed"); |
|||
exit(-1); |
|||
} |
|||
// tm = *utctime::tm_increment_hour(&tm, 8); |
|||
// logger->info("trace sendmsg_startCapture {}:{}", __FILE__, __LINE__); |
|||
return fmt::format("{:0>4}-{:0>2}{:0>2}-{:0>2}{:0>2}{:0>2}", tm.tm_year + 1900, // |
|||
tm.tm_mon + 1, // |
|||
tm.tm_mday, // |
|||
tm.tm_hour, // |
|||
tm.tm_min, tm.tm_sec); |
|||
} |
|||
|
|||
float DisinfectionService::getDisinfectionDValue(float ppm) { // |
|||
return m_dvalueComputer.computeDValue(ppm); |
|||
} |
|||
float DisinfectionService::computeNowLogLevel(DisinfectionContext& context) { |
|||
float dvalue = context.state_dvalue; |
|||
if (dvalue > 0) { |
|||
/** |
|||
* @brief 计算 state_now_loglevel |
|||
*/ |
|||
return context.state_now_loglevel + DVALUE_COMPUTEPERIOD_TIME_S / (dvalue * 60); |
|||
} |
|||
return context.state_now_loglevel; |
|||
} |
|||
|
|||
void DisinfectionService::computeRemainTime(DisinfectionContext& context) { |
|||
/** |
|||
* @brief 计算Dvalue |
|||
*/ |
|||
float dvalue = context.state_dvalue; |
|||
|
|||
if (dvalue > 0) { |
|||
/** |
|||
* @brief 计算 state_now_loglevel |
|||
*/ |
|||
if (context.cfg_targetLoglevel >= context.state_now_loglevel) { |
|||
context.state_remaintime = (context.cfg_targetLoglevel - context.state_now_loglevel) * (dvalue * 60); |
|||
} else { |
|||
context.state_remaintime = 0; |
|||
} |
|||
} else { |
|||
// |
|||
} |
|||
|
|||
logger->info("computeRemainTime minh2o2 {} dvalue {}", context.min_h2o2, dvalue); |
|||
} |
|||
|
|||
shared_ptr<DisinfectionLogger> DisinfectionService::createCSVLogger(string log_file_name) { |
|||
shared_ptr<DisinfectionLogger> _logger = m_disinfectionLogsManager->createNewLogger(log_file_name); |
|||
#if (defined PROJECT_TYPE_LARGE_SPACE_DISINFECTION) || (defined PROJECT_TYPE_SMALL_SPACE_DISINFECTION) |
|||
|
|||
_logger->write( |
|||
fmt::format("{}," |
|||
" {} , {} , {} , {} ," |
|||
" {} , {} , {} , {} ," |
|||
" {} , {} , {} , {} ," |
|||
" {} , {} , {} ," |
|||
" {} , {} , {} , {} ," |
|||
" {} , {}" |
|||
"\n", |
|||
ZIconv::noChange("时间"), // |
|||
ZIconv::noChange("仓内-气化过氧化氢浓度"), ZIconv::noChange("仓内-温度"), ZIconv::noChange("仓内-相对湿度"), ZIconv::noChange("仓内-相对饱和度"), // |
|||
ZIconv::noChange("环境1-气化过氧化氢浓度"), ZIconv::noChange("环境1-温度"), ZIconv::noChange("环境1-相对湿度"), ZIconv::noChange("环境1-相对饱和度"), // |
|||
ZIconv::noChange("环境2-气化过氧化氢浓度"), ZIconv::noChange("环境2-温度"), ZIconv::noChange("环境2-相对湿度"), ZIconv::noChange("环境2-相对饱和度"), // |
|||
ZIconv::noChange("D值"), ZIconv::noChange("当前LOG"), ZIconv::noChange("目标LOG"), // |
|||
ZIconv::noChange("加热器电源"), ZIconv::noChange("风机电源"), ZIconv::noChange("空压机电源"), ZIconv::noChange("喷液泵(g/min)"), // |
|||
ZIconv::noChange("消毒剩余剂量(g)"), ZIconv::noChange("剩余时间(s)"))); |
|||
#endif |
|||
|
|||
#ifdef PROJECT_TYPE_PIPE_DISINFECTION |
|||
|
|||
_logger->write( |
|||
fmt::format(" {} ," |
|||
" {} , {} , {} , {} ," |
|||
" {} , {} , {} ," |
|||
" {} , {} , {} , {} ," |
|||
" {} , {} " |
|||
"\n", |
|||
ZIconv::noChange("时间"), // |
|||
ZIconv::noChange("仓内-气化过氧化氢浓度"), ZIconv::noChange("仓内-温度"), ZIconv::noChange("仓内-相对湿度"), ZIconv::noChange("仓内-相对饱和度"), // |
|||
ZIconv::noChange("D值"), ZIconv::noChange("当前LOG"), ZIconv::noChange("目标LOG"), // |
|||
ZIconv::noChange("加热器电源"), ZIconv::noChange("风机电源"), ZIconv::noChange("空压机电源"), ZIconv::noChange("喷液泵(g/min)"), // |
|||
ZIconv::noChange("消毒剩余剂量(g)"), ZIconv::noChange("剩余时间(s)"))); |
|||
#endif |
|||
return _logger; |
|||
} |
|||
|
|||
void DisinfectionService::dumpDisinfectionLogsToCSV(DisinfectionContext& context) { |
|||
#if (defined PROJECT_TYPE_LARGE_SPACE_DISINFECTION) || (defined PROJECT_TYPE_SMALL_SPACE_DISINFECTION) |
|||
|
|||
static_assert(MAX_H2O2_SENSOR_NUM == 3, "MAX_H2O2_SENSOR_NUM must be 3"); |
|||
|
|||
auto& cx = context; |
|||
string h2o2str[MAX_H2O2_SENSOR_NUM]; |
|||
string tempstr[MAX_H2O2_SENSOR_NUM]; |
|||
string humidstr[MAX_H2O2_SENSOR_NUM]; |
|||
string satstr[MAX_H2O2_SENSOR_NUM]; |
|||
|
|||
for (int i = 0; i < MAX_H2O2_SENSOR_NUM; i++) { |
|||
h2o2str[i] = fmt::format("{}", cx.h2o2[i]); |
|||
tempstr[i] = fmt::format("{}", cx.temp[i]); |
|||
humidstr[i] = fmt::format("{}", cx.humid[i]); |
|||
satstr[i] = fmt::format("{}", cx.saturation[i]); |
|||
} |
|||
|
|||
for (int i = 0; i < MAX_H2O2_SENSOR_NUM; i++) { |
|||
if (cx.h2o2[i] < 0) h2o2str[i] = "N/A"; |
|||
if (cx.temp[i] < 0) tempstr[i] = "N/A"; |
|||
if (cx.humid[i] < 0) humidstr[i] = "N/A"; |
|||
if (cx.saturation[i] < 0) satstr[i] = "N/A"; |
|||
} |
|||
|
|||
auto ds = m_deviceIoControlService; |
|||
float dvalue = 0; |
|||
if (m_context.state_dvalue <= 0) { |
|||
dvalue = 0; |
|||
} else { |
|||
dvalue = m_context.state_dvalue; |
|||
} |
|||
|
|||
int remaintime = getEstimatedRemainingTimeS(); |
|||
|
|||
context.csvlogger->write( |
|||
fmt::format(" {} ," |
|||
" {} , {} , {} , {} ," |
|||
" {} , {} , {} , {} ," |
|||
" {} , {} , {} , {} ," |
|||
" {} , {} , {} ," |
|||
" {} , {} , {} , {} ," |
|||
" {} , {} " |
|||
"\n", |
|||
getTime(), // |
|||
h2o2str[0], tempstr[0], humidstr[0], satstr[0], // |
|||
h2o2str[1], tempstr[1], humidstr[1], satstr[1], // |
|||
h2o2str[2], tempstr[2], humidstr[2], satstr[2], // |
|||
(int32_t)dvalue, (int32_t)m_context.state_now_loglevel, (int32_t)m_context.cfg_targetLoglevel, // |
|||
ds->heatingStrip_getstate(), ds->airBlower_getstate(), ds->airCompressor_getstate(), ds->sprayLiquidPump_getGPM(), // |
|||
m_deviceIoControlService->getDisinfectantVolume_g(), formattimeS(remaintime))); |
|||
#endif |
|||
|
|||
#ifdef PROJECT_TYPE_PIPE_DISINFECTION |
|||
|
|||
static_assert(MAX_H2O2_SENSOR_NUM == 1, "MAX_H2O2_SENSOR_NUM must be 1"); |
|||
|
|||
auto& cx = context; |
|||
string h2o2str[MAX_H2O2_SENSOR_NUM]; |
|||
string tempstr[MAX_H2O2_SENSOR_NUM]; |
|||
string humidstr[MAX_H2O2_SENSOR_NUM]; |
|||
string satstr[MAX_H2O2_SENSOR_NUM]; |
|||
|
|||
for (int i = 0; i < MAX_H2O2_SENSOR_NUM; i++) { |
|||
h2o2str[i] = fmt::format("{}", cx.h2o2[i]); |
|||
tempstr[i] = fmt::format("{}", cx.temp[i]); |
|||
humidstr[i] = fmt::format("{}", cx.humid[i]); |
|||
satstr[i] = fmt::format("{}", cx.saturation[i]); |
|||
} |
|||
|
|||
for (int i = 0; i < MAX_H2O2_SENSOR_NUM; i++) { |
|||
if (cx.h2o2[i] < 0) h2o2str[i] = "N/A"; |
|||
if (cx.temp[i] < 0) tempstr[i] = "N/A"; |
|||
if (cx.humid[i] < 0) humidstr[i] = "N/A"; |
|||
if (cx.saturation[i] < 0) satstr[i] = "N/A"; |
|||
} |
|||
|
|||
auto ds = m_deviceIoControlService; |
|||
float dvalue = 0; |
|||
if (m_context.state_dvalue <= 0) { |
|||
dvalue = 0; |
|||
} else { |
|||
dvalue = m_context.state_dvalue; |
|||
} |
|||
|
|||
int remaintime = getEstimatedRemainingTimeS(); |
|||
|
|||
context.csvlogger->write( |
|||
fmt::format(" {} ," |
|||
" {} , {} , {} , {} ," |
|||
" {} , {} , {} ," |
|||
" {} , {} , {} , {} ," |
|||
" {} , {} " |
|||
"\n", |
|||
getTime(), // |
|||
h2o2str[0], tempstr[0], humidstr[0], satstr[0], // |
|||
(int32_t)dvalue, (int32_t)m_context.state_now_loglevel, (int32_t)m_context.cfg_targetLoglevel, // |
|||
ds->heatingStrip_getstate(), ds->airBlower_getstate(), ds->airCompressor_getstate(), ds->sprayLiquidPump_getGPM(), // |
|||
m_deviceIoControlService->getDisinfectantVolume_g(), formattimeS(remaintime))); |
|||
|
|||
#endif |
|||
} |
|||
|
|||
void DisinfectionService::pushDisinfectionPrinterTask(DisinfectionContext& context) { // |
|||
shared_ptr<DisinfectionPrinterTask> task = make_shared<DisinfectionPrinterTask>(); |
|||
auto ds = GET_SERVICE(DeviceStateService); |
|||
auto dio = m_deviceIoControlService; |
|||
|
|||
task->start_tp = context.start_tp; |
|||
task->complete_tp = context.complete_tp; |
|||
task->stateSnapshotList = context.stateSnapshotList; |
|||
task->disinfectantUsage = context.beforeDisinfectantVolume_g - context.afterDisinfectantVolume_g; |
|||
task->disinfection_id = context.m_disinfectionID; |
|||
task->usr = ds->getLoginUid(); |
|||
|
|||
task->targetLog = context.cfg_targetLoglevel; |
|||
task->actualLog = context.state_now_loglevel; |
|||
|
|||
m_disinfectionPrinterService->pushPrintTask(task); |
|||
} |
|||
|
|||
void DisinfectionService::log(DisinfectionContext& context) { |
|||
#if (defined PROJECT_TYPE_LARGE_SPACE_DISINFECTION) || (defined PROJECT_TYPE_SMALL_SPACE_DISINFECTION) |
|||
|
|||
auto& cx = context; |
|||
auto ds = m_deviceIoControlService; |
|||
float dvalue = 0; |
|||
if (m_context.state_dvalue <= 0) { |
|||
dvalue = 0; |
|||
} else { |
|||
dvalue = m_context.state_dvalue; |
|||
} |
|||
|
|||
int remaintime = getEstimatedRemainingTimeS(); |
|||
|
|||
logger->info( |
|||
fmt::format("{}," |
|||
"s0({},{},{},{})," |
|||
"s1({},{},{},{})," |
|||
"s2({},{},{},{})," |
|||
"min_h2o2:{},max_h2o2:{},max_hum:{},max_sa:{}," |
|||
"dv:{},log:{},tlog:{}," |
|||
"h:{},airB:{},airC:{},pump:{}," |
|||
"g:{},remainS:{}" |
|||
"\n", |
|||
getTime(), // |
|||
cx.h2o2[0], cx.temp[0], cx.humid[0], cx.saturation[0], // |
|||
cx.h2o2[1], cx.temp[1], cx.humid[1], cx.saturation[1], // |
|||
cx.h2o2[2], cx.temp[2], cx.humid[2], cx.saturation[2], // |
|||
m_context.min_h2o2, m_context.max_h2o2, m_context.max_humid, m_context.max_saturation, // |
|||
(int32_t)dvalue, m_context.state_now_loglevel, (int32_t)m_context.cfg_targetLoglevel, // |
|||
ds->heatingStrip_getstate(), ds->airBlower_getstate(), ds->airCompressor_getstate(), ds->sprayLiquidPump_getGPM(), // |
|||
m_deviceIoControlService->getDisinfectantVolume_g(), formattimeS(remaintime))); |
|||
#endif |
|||
#ifdef PROJECT_TYPE_PIPE_DISINFECTION |
|||
auto& cx = context; |
|||
auto ds = m_deviceIoControlService; |
|||
float dvalue = 0; |
|||
if (m_context.state_dvalue <= 0) { |
|||
dvalue = 0; |
|||
} else { |
|||
dvalue = m_context.state_dvalue; |
|||
} |
|||
|
|||
int remaintime = getEstimatedRemainingTimeS(); |
|||
|
|||
logger->info( |
|||
fmt::format("{}," |
|||
"s0({},{},{},{})," |
|||
"min_h2o2:{},max_h2o2:{},max_hum:{},max_sa:{}," |
|||
"dv:{},log:{},tlog:{}," |
|||
"h:{},airB:{},airC:{},pump:{}," |
|||
"g:{},remainS:{}" |
|||
"\n", |
|||
getTime(), // |
|||
cx.h2o2[0], cx.temp[0], cx.humid[0], cx.saturation[0], // |
|||
m_context.min_h2o2, m_context.max_h2o2, m_context.max_humid, m_context.max_saturation, // |
|||
(int32_t)dvalue, m_context.state_now_loglevel, (int32_t)m_context.cfg_targetLoglevel, // |
|||
ds->heatingStrip_getstate(), ds->airBlower_getstate(), ds->airCompressor_getstate(), ds->sprayLiquidPump_getGPM(), // |
|||
m_deviceIoControlService->getDisinfectantVolume_g(), formattimeS(remaintime))); |
|||
#endif |
|||
} |
|||
|
|||
/******************************************************************************* |
|||
* WORK * |
|||
*******************************************************************************/ |
|||
|
|||
void DisinfectionService::initContext(DisinfectionContext& context, // |
|||
int loglevel, // |
|||
float injection_pump_speed, // |
|||
float stoped_gs, // |
|||
float continued_gs, // |
|||
float stoped_satur, // |
|||
float continued_satur, // |
|||
float stoped_humi, // |
|||
float continued_humi // |
|||
) { |
|||
context.m_disinfectionID = createDisinfectionID(); |
|||
context.pre_heat_time_s = m_dbService->getSettingVal("pre_heat_time_s"); |
|||
context.stoped_gs = stoped_gs; |
|||
context.continued_gs = continued_gs; |
|||
context.stoped_satur = stoped_satur; |
|||
context.continued_satur = continued_satur; |
|||
context.stoped_humi = stoped_humi; |
|||
context.continued_humi = continued_humi; |
|||
context.injection_pump_speed = injection_pump_speed; |
|||
context.injection_pump_speed_changed = true; |
|||
|
|||
if (g_in_test) { |
|||
logger->warn("in test mode, pre_heat_time_s = 5"); |
|||
context.pre_heat_time_s = 5; |
|||
} |
|||
|
|||
logger->info("startDisinfection {} {}", m_context.cfg_targetLoglevel, m_context.m_disinfectionID); |
|||
logger->info(" stoped_gs {}", context.stoped_gs); |
|||
logger->info(" continued_gs {}", context.continued_gs); |
|||
logger->info(" stoped_satur {}", context.stoped_satur); |
|||
logger->info(" continued_satur {}", context.continued_satur); |
|||
logger->info(" stoped_humi {}", context.stoped_humi); |
|||
logger->info(" continued_humi {}", context.continued_humi); |
|||
logger->info(" pre_heat_time_s {}", context.pre_heat_time_s); |
|||
logger->info(""); |
|||
|
|||
context.state_remaintime = context.pre_heat_time_s + loglevel * 90 * 60; // 计算总的加热时间 |
|||
m_disinfectionWorkState = 1; |
|||
context.cfg_targetLoglevel = loglevel; |
|||
context.state_now_loglevel = 0; |
|||
m_context.state_dvalue = 0; |
|||
|
|||
m_context.m_state = kstate_preheat; |
|||
|
|||
m_context.start_tp = zsystem_clock().now(); |
|||
m_context.start_steady_tp = zsteady_clock().now(); |
|||
for (int i = 0; i < MAX_H2O2_SENSOR_NUM; i++) { |
|||
m_context.h2o2[i] = 0; |
|||
m_context.humid[i] = 0; |
|||
m_context.temp[i] = 0; |
|||
m_context.saturation[i] = 0; |
|||
} |
|||
|
|||
m_context.min_h2o2 = 0; |
|||
m_context.max_h2o2 = 0; |
|||
m_context.max_humid = 0; |
|||
m_context.max_saturation = 0; |
|||
m_context.stateSnapshotList.clear(); |
|||
m_context.afterDisinfectantVolume_g = 0; |
|||
|
|||
#if (defined PROJECT_TYPE_LARGE_SPACE_DISINFECTION) || (defined PROJECT_TYPE_SMALL_SPACE_DISINFECTION) || (defined PROJECT_TYPE_PIPE_DISINFECTION) |
|||
m_context.beforeDisinfectantVolume_g = m_deviceIoControlService->getDisinfectantVolume_g(); |
|||
#elif (defined PROJECT_TYPE_DRAW_BAR_BOX) |
|||
m_context.beforeDisinfectantVolume_g = 0; |
|||
#else |
|||
#endif |
|||
|
|||
#if (defined PROJECT_TYPE_LARGE_SPACE_DISINFECTION) || (defined PROJECT_TYPE_SMALL_SPACE_DISINFECTION) |
|||
m_deviceIoControlService->warningLightCtrl(0, 0, 1, 0); |
|||
#endif |
|||
|
|||
#ifdef PROJECT_TYPE_PIPE_DISINFECTION |
|||
m_deviceIoControlService->warningLightCtrl(1, 1, 0, 0); |
|||
#endif |
|||
|
|||
#if (defined PROJECT_TYPE_LARGE_SPACE_DISINFECTION) || (defined PROJECT_TYPE_SMALL_SPACE_DISINFECTION) || (defined PROJECT_TYPE_PIPE_DISINFECTION) |
|||
m_deviceIoControlService->heartingPlate_setPower(true); |
|||
m_deviceIoControlService->airBlower_setState(true); |
|||
#elif (defined PROJECT_TYPE_DRAW_BAR_BOX) |
|||
#else |
|||
#endif |
|||
|
|||
context.csvlogger = createCSVLogger(context.m_disinfectionID); |
|||
|
|||
m_context.firstLog = true; |
|||
} |
|||
|
|||
void DisinfectionService::finishDisinfection(DisinfectionContext& context) { |
|||
context.state_remaintime = 0; |
|||
logger->info("stop disinfection {}", context.m_disinfectionID); |
|||
|
|||
#if (defined PROJECT_TYPE_LARGE_SPACE_DISINFECTION) || (defined PROJECT_TYPE_SMALL_SPACE_DISINFECTION) || (defined PROJECT_TYPE_PIPE_DISINFECTION) |
|||
// sprayLiquidPump_close(); |
|||
m_deviceIoControlService->sprayLiquidPump_close(); |
|||
usleep(1000 * 1000); |
|||
// airCompressor(false); |
|||
m_deviceIoControlService->airCompressor_setState(false); |
|||
usleep(1000 * 1000); |
|||
// blower_setPower(false); |
|||
m_deviceIoControlService->airBlower_setState(false); |
|||
usleep(1000 * 1000); |
|||
// heartingPlate_setPower(false); |
|||
m_deviceIoControlService->heartingPlate_setPower(false); |
|||
m_disinfectionWorkState = 3; |
|||
|
|||
m_deviceIoControlService->warningLightCtrl(0, 1, 0, 0); |
|||
#elif (defined PROJECT_TYPE_DRAW_BAR_BOX) |
|||
#else |
|||
#endif |
|||
} |
|||
|
|||
void DisinfectionService::processPreheatState(DisinfectionContext& context) { |
|||
int hasstarttime = zsteady_clock().elapsedTimeS(context.start_steady_tp); |
|||
|
|||
// logger->info("preheat {}", context.m_disinfectionID); |
|||
if ((context.m_state == kstate_preheat && hasstarttime > m_context.pre_heat_time_s)) { |
|||
/** |
|||
* @brief |
|||
* 预热结束 |
|||
*/ |
|||
logger->info("preheat finished {}", context.m_disinfectionID); |
|||
logger->info("preheat finished {}", context.m_disinfectionID); |
|||
|
|||
#ifdef PROJECT_TYPE_PIPE_DISINFECTION |
|||
m_deviceIoControlService->airCompressor_channelSelect(1); |
|||
m_deviceIoControlService->airCompressor_setValve1(1); |
|||
m_deviceIoControlService->airCompressor_setValve2(1); |
|||
#endif |
|||
|
|||
#if (defined PROJECT_TYPE_LARGE_SPACE_DISINFECTION) || (defined PROJECT_TYPE_SMALL_SPACE_DISINFECTION) || (defined PROJECT_TYPE_PIPE_DISINFECTION) |
|||
m_deviceIoControlService->airBlower_setState(true); |
|||
usleep(1000 * 1000); |
|||
m_deviceIoControlService->airCompressor_setState(true); |
|||
usleep(1000 * 1000); |
|||
m_deviceIoControlService->sprayLiquidPump_open(context.injection_pump_speed); |
|||
#elif (defined PROJECT_TYPE_DRAW_BAR_BOX) |
|||
m_deviceIoControlService->DBDB__sprayAirCompressorPowerCtrl(1); |
|||
usleep(1000 * 1000); |
|||
m_deviceIoControlService->DBDB__heaterCtrl(1); |
|||
usleep(100 * 1000); |
|||
m_deviceIoControlService->DBDB__heaterCtrlSafeValve(1); |
|||
usleep(100 * 1000); |
|||
m_deviceIoControlService->DBDB__miniPwmBlowerCtrl(1); |
|||
usleep(100 * 1000); |
|||
m_deviceIoControlService->DBDB__extValveCtrl(IF_DeviceIoContrlService::kExtValveChannel_disinfectionChannel); |
|||
#else |
|||
#endif |
|||
|
|||
context.m_state = kstate_disinfection; |
|||
} else { |
|||
logger->info("{}: preheat {}", context.m_disinfectionID, m_context.pre_heat_time_s - hasstarttime); |
|||
} |
|||
} |
|||
|
|||
/** |
|||
* @brief |
|||
* 消毒中状态处理 |
|||
*/ |
|||
void DisinfectionService::processDisinfectionState(DisinfectionContext& context) { |
|||
/** |
|||
* @brief 周期性计算剩余时间 |
|||
*/ |
|||
|
|||
/** |
|||
* @brief 根据湿度启停喷雾 |
|||
*/ |
|||
if (!m_context.state_is_disinfection_take_break) { |
|||
/** |
|||
* @brief 检查当前 |
|||
*/ |
|||
float nowSatur = m_context.max_saturation; |
|||
float nowh2o2 = m_context.max_h2o2; |
|||
float humid = m_context.max_humid; |
|||
|
|||
if (m_context.injection_pump_speed_changed) { |
|||
#if (defined PROJECT_TYPE_LARGE_SPACE_DISINFECTION) || (defined PROJECT_TYPE_SMALL_SPACE_DISINFECTION) || (defined PROJECT_TYPE_PIPE_DISINFECTION) |
|||
m_deviceIoControlService->sprayLiquidPump_open(context.injection_pump_speed); |
|||
#elif (defined PROJECT_TYPE_DRAW_BAR_BOX) |
|||
#else |
|||
#endif |
|||
|
|||
m_context.injection_pump_speed_changed = false; |
|||
} |
|||
|
|||
// humid > m_context.stoped_satur |
|||
if (nowSatur > m_context.stoped_satur || nowh2o2 > m_context.stoped_gs || humid > m_context.stoped_humi) { |
|||
logger->info("stop sprayLiquid"); |
|||
|
|||
#if (defined PROJECT_TYPE_LARGE_SPACE_DISINFECTION) || (defined PROJECT_TYPE_SMALL_SPACE_DISINFECTION) || (defined PROJECT_TYPE_PIPE_DISINFECTION) |
|||
m_deviceIoControlService->sprayLiquidPump_close(); |
|||
usleep(1000 * 1000); |
|||
m_deviceIoControlService->airCompressor_setState(false); |
|||
#elif (defined PROJECT_TYPE_DRAW_BAR_BOX) |
|||
#else |
|||
#endif |
|||
|
|||
// m_context.sprayLiquidFlag = false; |
|||
m_context.state_is_disinfection_take_break = true; |
|||
} |
|||
} else { |
|||
float nowSatur = m_context.max_saturation; |
|||
float nowh2o2 = m_context.max_h2o2; |
|||
float humid = m_context.max_humid; |
|||
|
|||
// && humid < m_context.continued_satur |
|||
if (nowSatur < m_context.continued_satur && nowh2o2 < m_context.continued_gs && humid < context.continued_humi) { |
|||
logger->info("start sprayLiquid"); |
|||
|
|||
#if (defined PROJECT_TYPE_LARGE_SPACE_DISINFECTION) || (defined PROJECT_TYPE_SMALL_SPACE_DISINFECTION) || (defined PROJECT_TYPE_PIPE_DISINFECTION) |
|||
m_deviceIoControlService->sprayLiquidPump_open(context.injection_pump_speed); |
|||
usleep(1000 * 1000); |
|||
m_deviceIoControlService->airCompressor_setState(true); |
|||
#elif (defined PROJECT_TYPE_DRAW_BAR_BOX) |
|||
#else |
|||
#endif |
|||
|
|||
m_context.state_is_disinfection_take_break = false; |
|||
} |
|||
} |
|||
} |
|||
|
|||
void DisinfectionService::processState_Preheat(DisinfectionContext& context) { |
|||
/** |
|||
* @brief 预热中 |
|||
*/ |
|||
m_context.state_dvalue = 0; |
|||
processPreheatState(m_context); |
|||
} |
|||
|
|||
void DisinfectionService::processState_Disinfection(DisinfectionContext& context, bool& updatedval) { |
|||
m_context.state_dvalue = getDisinfectionDValue(m_context.min_h2o2); |
|||
if (zsteady_clock().elapsedTimeS(m_context.state_last_compute_dvalue_tp) > DVALUE_COMPUTEPERIOD_TIME_S) { |
|||
m_context.state_last_compute_dvalue_tp = zsteady_clock().now(); |
|||
m_context.state_now_loglevel = computeNowLogLevel(m_context); |
|||
computeRemainTime(m_context); |
|||
updatedval = true; |
|||
} |
|||
|
|||
/** |
|||
* @brief 消毒中 |
|||
*/ |
|||
processDisinfectionState(m_context); |
|||
// |
|||
if (m_context.state_remaintime <= 0 && m_context.state_now_loglevel > (m_context.cfg_targetLoglevel + 0.01)) { |
|||
m_context.state_remaintime = 0; |
|||
m_context.state_now_loglevel = m_context.cfg_targetLoglevel + 0.01; |
|||
logger->info("disinfection finished {},but waitting for h2o2 to safe", m_context.m_disinfectionID); |
|||
|
|||
#if (defined PROJECT_TYPE_LARGE_SPACE_DISINFECTION) || (defined PROJECT_TYPE_SMALL_SPACE_DISINFECTION) || (defined PROJECT_TYPE_PIPE_DISINFECTION) |
|||
m_deviceIoControlService->sprayLiquidPump_close(); |
|||
usleep(1000 * 1000); |
|||
m_deviceIoControlService->airCompressor_setState(false); |
|||
usleep(1000 * 1000); |
|||
m_deviceIoControlService->heartingPlate_setPower(false); |
|||
#elif (defined PROJECT_TYPE_DRAW_BAR_BOX) |
|||
#else |
|||
#endif |
|||
|
|||
m_context.m_state = kstate_degradation; |
|||
} |
|||
} |
|||
void DisinfectionService::processState_Degradation(DisinfectionContext& context) { |
|||
// 降解 |
|||
m_context.state_dvalue = 0; |
|||
logger->info("waitting for h2o2 concentration to safe value {}=>{}", m_context.min_h2o2, 1); |
|||
if (m_context.min_h2o2 < 1) { |
|||
logger->info("h2o2 concentration to safe value"); |
|||
m_context.m_state = kstate_finished; |
|||
} |
|||
} |
|||
|
|||
void DisinfectionService::disinfectionLoop(bool& breakflag) { |
|||
// logger->info("disinfection running {} {}s preheatFlag:{}", m_context.m_disinfectionID, m_context.state_remaintime, m_context.m_preheatFlag); |
|||
ThisThread thisThread; |
|||
disinfection_state_t enterstate; |
|||
disinfection_state_t exitstate; |
|||
bool statechanged = false; |
|||
bool updatedval = false; |
|||
|
|||
enterstate = m_context.m_state; |
|||
m_context.state_remaintime--; |
|||
|
|||
if (m_context.state_remaintime < 0) m_context.state_remaintime = 0; |
|||
updateH2O2SensorData(m_context); |
|||
|
|||
/******************************************************************************* |
|||
* 状态处理 * |
|||
*******************************************************************************/ |
|||
if (thisThread.getExitFlag()) { |
|||
m_context.m_state = kstate_finished; |
|||
} else if (m_context.m_state == kstate_preheat) { |
|||
processState_Preheat(m_context); |
|||
} else if (m_context.m_state == kstate_disinfection) { |
|||
processState_Disinfection(m_context, updatedval); |
|||
} else if (m_context.m_state == kstate_degradation) { |
|||
processState_Degradation(m_context); |
|||
} |
|||
|
|||
exitstate = m_context.m_state; |
|||
if (exitstate != enterstate) { |
|||
statechanged = true; |
|||
} |
|||
|
|||
/******************************************************************************* |
|||
* 打印日志 * |
|||
*******************************************************************************/ |
|||
if (exitstate == kstate_finished) { |
|||
/** |
|||
* @brief 消毒结束 |
|||
*/ |
|||
breakflag = true; |
|||
m_context.complete_tp = zsystem_clock().now(); |
|||
#if (defined PROJECT_TYPE_LARGE_SPACE_DISINFECTION) || (defined PROJECT_TYPE_SMALL_SPACE_DISINFECTION) || (defined PROJECT_TYPE_PIPE_DISINFECTION) |
|||
m_context.afterDisinfectantVolume_g = m_deviceIoControlService->getDisinfectantVolume_g(); |
|||
#elif (defined PROJECT_TYPE_DRAW_BAR_BOX) |
|||
m_context.afterDisinfectantVolume_g = 0; |
|||
#else |
|||
m_context.afterDisinfectantVolume_g = 0; |
|||
#endif |
|||
|
|||
if (m_context.m_state != kstate_finished) { |
|||
m_context.m_state = kstate_finished; |
|||
} |
|||
m_disinfectionWorkState = 0; |
|||
takeStateSnapshot(m_context); |
|||
dumpDisinfectionLogsToCSV(m_context); |
|||
log(m_context); |
|||
pushDisinfectionPrinterTask(m_context); |
|||
finishDisinfection(m_context); |
|||
m_context.csvlogger = nullptr; |
|||
} else { |
|||
if (updatedval) { |
|||
log(m_context); |
|||
} |
|||
|
|||
if (statechanged || zsteady_clock().elapsedTimeS(m_context.state_lastlog_tp) > DUMP_LOG_PERIOD) { |
|||
m_context.state_lastlog_tp = zsteady_clock().now(); |
|||
takeStateSnapshot(m_context); |
|||
dumpDisinfectionLogsToCSV(m_context); |
|||
} |
|||
} |
|||
} |
|||
|
|||
void DisinfectionService::changeDisinfectionParameter(int injection_pump_speed, // |
|||
int stoped_gs, // |
|||
int continued_gs, // |
|||
int stoped_satur, // |
|||
int continued_satur, // |
|||
int stoped_humi, // |
|||
int continued_humi) { |
|||
lock_guard<recursive_mutex> lock(lock_); |
|||
m_context.injection_pump_speed = injection_pump_speed; |
|||
m_context.stoped_gs = stoped_gs; |
|||
m_context.continued_gs = continued_gs; |
|||
m_context.stoped_satur = stoped_satur; |
|||
m_context.continued_satur = continued_satur; |
|||
m_context.stoped_humi = stoped_humi; |
|||
m_context.continued_humi = continued_humi; |
|||
m_context.injection_pump_speed_changed = true; |
|||
|
|||
logger->info("changeDisinfectionParameter {} {} {} {} {} {} {}", // |
|||
injection_pump_speed, stoped_gs, continued_gs, stoped_satur, continued_satur, stoped_humi, continued_humi); |
|||
} |
|||
|
|||
void DisinfectionService::startDisinfection(int loglevel, // |
|||
int injection_pump_speed, // |
|||
int stoped_gs, // |
|||
int continued_gs, // |
|||
int stoped_satur, // |
|||
int continued_satur, // |
|||
int stoped_humi, // |
|||
int continued_humi // |
|||
) { |
|||
lock_guard<recursive_mutex> lock(lock_); |
|||
|
|||
if (m_disinfectionThread) stopDisinfection(); |
|||
|
|||
initContext(m_context, loglevel, injection_pump_speed, stoped_gs, continued_gs, stoped_satur, continued_satur, stoped_humi, continued_humi); |
|||
m_disinfectionThread.reset(new Thread("m_disinfectionThread", [this]() { |
|||
ThisThread thisThread; |
|||
while (true) { |
|||
thisThread.sleepForMs(1000); |
|||
bool breakflag = false; |
|||
disinfectionLoop(breakflag); |
|||
if (breakflag) { |
|||
break; |
|||
} |
|||
} |
|||
})); |
|||
// |
|||
} |
|||
void DisinfectionService::stopDisinfection() { |
|||
lock_guard<recursive_mutex> lock(lock_); |
|||
if (m_disinfectionThread) { |
|||
m_disinfectionThread->join(); |
|||
m_disinfectionThread = nullptr; |
|||
} |
|||
} |
|||
|
|||
int DisinfectionService::getDisinfectionWorkState() { return m_context.m_state; } |
|||
|
|||
int32_t DisinfectionService::getEstimatedRemainingTimeS() { |
|||
if (m_context.m_state == kstate_preheat) { |
|||
return getPreHeatRaminTimeS(); |
|||
} else if (m_context.m_state == kstate_disinfection) { |
|||
if (m_context.state_dvalue > 0) { |
|||
return m_context.state_remaintime; |
|||
} else { |
|||
return -1; |
|||
} |
|||
} else { |
|||
return 0; |
|||
} |
|||
} |
|||
int32_t DisinfectionService::getPreHeatRaminTimeS() { |
|||
int32_t remaintime = 0; |
|||
if (m_context.m_state == kstate_preheat) { |
|||
remaintime = m_context.pre_heat_time_s - zsteady_clock().elapsedTimeS(m_context.start_steady_tp); |
|||
if (remaintime < 0) { |
|||
remaintime = 0; |
|||
} |
|||
return remaintime; |
|||
} else { |
|||
return 0; |
|||
} |
|||
} |
|||
|
|||
string DisinfectionService::getDisinfectionID() { return m_context.m_disinfectionID; } |
|||
bool DisinfectionService::isPreheatState() { return m_context.m_state == kstate_preheat; } |
|||
void DisinfectionService::updateH2O2SensorData(DisinfectionContext& context) { |
|||
auto& cx = context; |
|||
for (size_t i = 0; i < MAX_H2O2_SENSOR_NUM; i++) { |
|||
cx.h2o2[i] = m_deviceIoControlService->H2O2Sensor_readH2O2PPM(i); |
|||
} |
|||
|
|||
for (size_t i = 0; i < MAX_H2O2_SENSOR_NUM; i++) { |
|||
cx.humid[i] = m_deviceIoControlService->H2O2Sensor_readHumid(i); |
|||
} |
|||
|
|||
for (size_t i = 0; i < MAX_H2O2_SENSOR_NUM; i++) { |
|||
cx.temp[i] = m_deviceIoControlService->H2O2Sensor_readTemperature(i); |
|||
} |
|||
|
|||
for (size_t i = 0; i < MAX_H2O2_SENSOR_NUM; i++) { |
|||
cx.saturation[i] = m_deviceIoControlService->H2O2Sensor_readSaturation(i); |
|||
} |
|||
|
|||
cx.min_h2o2 = cx.h2o2[0]; |
|||
cx.max_h2o2 = cx.h2o2[0]; |
|||
cx.max_humid = cx.humid[0]; |
|||
cx.max_saturation = cx.saturation[0]; |
|||
|
|||
for (size_t i = 0; i < MAX_H2O2_SENSOR_NUM; i++) { |
|||
if (cx.h2o2[i] < cx.min_h2o2) { |
|||
cx.min_h2o2 = cx.h2o2[i]; |
|||
} |
|||
|
|||
if (cx.h2o2[i] > cx.max_h2o2) { |
|||
cx.max_h2o2 = cx.h2o2[i]; |
|||
} |
|||
|
|||
if (cx.humid[i] > cx.max_humid) { |
|||
cx.max_humid = cx.humid[i]; |
|||
} |
|||
|
|||
if (cx.saturation[i] > cx.max_saturation) { |
|||
cx.max_saturation = cx.saturation[i]; |
|||
} |
|||
} |
|||
|
|||
if (cx.max_h2o2 < 0) cx.max_h2o2 = 0; |
|||
if (cx.min_h2o2 < 0) cx.min_h2o2 = 0; |
|||
if (cx.max_humid < 0) cx.max_humid = 0; |
|||
if (cx.max_saturation < 0) cx.max_saturation = 0; |
|||
} |
|||
|
|||
void DisinfectionService::takeStateSnapshot(DisinfectionContext& context) { |
|||
auto& cx = context; |
|||
|
|||
shared_ptr<StateSnapshot> snapshot = make_shared<StateSnapshot>(); |
|||
snapshot->time = zsystem_clock().now(); |
|||
for (size_t i = 0; i < MAX_H2O2_SENSOR_NUM; i++) { |
|||
snapshot->h2o2[i] = cx.h2o2[i]; |
|||
snapshot->humid[i] = cx.humid[i]; |
|||
snapshot->temp[i] = cx.temp[i]; |
|||
snapshot->saturation[i] = cx.saturation[i]; |
|||
} |
|||
|
|||
snapshot->min_h2o2 = cx.min_h2o2; |
|||
snapshot->max_h2o2 = cx.max_h2o2; |
|||
snapshot->max_humid = cx.max_humid; |
|||
snapshot->max_saturation = cx.max_saturation; |
|||
snapshot->state = cx.m_state; |
|||
snapshot->dloglevel = cx.state_now_loglevel; |
|||
cx.stateSnapshotList.push_back(snapshot); |
|||
} |
Write
Preview
Loading…
Cancel
Save