You can not select more than 25 topics
Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.
2.1 KiB
2.1 KiB
1. 光栅逻辑
2. 点击耗材扫描时,查询所有耗材对应的项目的温度,如果温度不一致,提醒用户需要先设置温度。
3. BUG-后台程序发送can消息报send frame overtime,重启后台程序后恢复
[25-01-03 16:48:14.582] [ExtAPIService ] [I] down can bin -> 2C0E010004005B00(16)
[25-01-03 16:48:16.686] [ExtAPIService ] [I] down can bin -> 2D0E010004005B00(16)
[25-01-03 16:48:16.686] [ExtAPIService ] [I] down can bin -> 2D0E010004005B00(16)
[25-01-03 16:48:16.706] [SocketCan ] [E] send frame overtime
[25-01-03 16:48:18.788] [ExtAPIService ] [I] down can bin -> 2E0E010004005B00(16)
[25-01-03 16:48:18.809] [SocketCan ] [E] send frame overtime
[25-01-03 16:48:20.893] [ExtAPIService ] [I] down can bin -> 2F0E010004005B00(16)
[25-01-03 16:48:20.913] [SocketCan ] [E] send frame overtime
[25-01-03 16:48:22.994] [ExtAPIService ] [I] down can bin -> 300E010004005B00(16)
[25-01-03 16:48:23.014] [SocketCan ] [E] send frame overtime
[25-01-03 16:48:25.096] [ExtAPIService ] [I] down can bin -> 310E010001005B00(16)
[25-01-03 16:48:25.117] [SocketCan ] [E] send frame overtime
[25-01-03 16:48:27.200] [ExtAPIService ] [I] down can bin -> 320E010001005B00(16)
[25-01-03 16:48:27.220] [SocketCan ] [E] send frame overtime
[25-01-03 16:48:29.301] [ExtAPIService ] [I] down can bin -> 330E010001005B00(16)
[25-01-03 16:48:29.321] [SocketCan ] [E] send frame overtime
[25-01-03 16:48:31.401] [ExtAPIService ] [I] down can bin -> 340E010001005B00(16)
[25-01-03 16:48:31.422] [SocketCan ] [E] send frame overtime
[25-01-03 16:48:33.504] [ExtAPIService ] [I] down can bin -> 350E010001005B00(16)
[25-01-03 16:48:33.525] [SocketCan ] [E] send frame overtime
4. 处理一下A8kEcode.APPE_TAKE_TIP_FAIL错误
5. 设备启动后,去3个TIP区域尝试取一个TIP头,如果取不到,说明TIP头数量设置错误,暂停设备,提醒用户检查TIP头数量设置